Sign In | Join Free | My burrillandco.com
Home > Thermal Shock Chamber >

3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz

ATMARS INDUSTRTY CO., LIMITED
Contact Now
    Buy cheap 3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz from wholesalers
     
    Buy cheap 3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz from wholesalers
    • Buy cheap 3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz from wholesalers
    • Buy cheap 3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz from wholesalers
    • Buy cheap 3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz from wholesalers
    • Buy cheap 3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz from wholesalers

    3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz

    Ask Lasest Price
    Brand Name : ATMARS
    Model Number : AS3-72 SERIES
    Certification : ISO, CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 35 Sets Per Month
    Delivery Time : 25 Working Days
    • Product Details
    • Company Profile

    3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz

    3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz


    Electrical
    All circuits fused or circuit breaker protected
    All wiring labeled or color coded
    Fully enclosed electrical panel
    High Temperature limit safety
    Balanced load on 3 phase power
    What is a Three -Zone Thermal Shock Chamber ?
    3-Zone Thermal Shock Chambers from ATMARS has three side-by-side independent zones: hot, ambient, and cold. The addition of the ambient zone allows for three zone testing, which is a requirement of some military standards.

    General Performance of ATMARS Three Zone Thermal Shock Test Chambers
    AS3 Series Three Zone (Hot/Ambient/Cold) Horizontal Layout (side by side) - direct hot/cold transfer with selectable ambient temperature dwell required for some MIL-STD's.
    Our standard three-zone thermal shock chambers models workspace volumes include: 72L, 100L, 150L, 200L, 252L, 300L and 480L. And interior dimensions can be customized according to specimen sizes and your testing requirements.
    Temperature Range:
    - Hot zone to +180℃ (356° F)
    - Cold zone to -75℃ (-103° F)
    - Other temperature range available
    High temperature exposure: +150℃ (302° F)
    Low temperature exposure:
    Type A: -40℃ (-40° F)
    Type B: -55℃ (-67° F)
    Type C: -65℃ (-85° F)
    Recovery time for mechanical refrigeration : ≤ 5minutes
    High / Low temperature exposure time: 30minutes
    An ATMARS application engineer can assist you in selecting the chamber configuration and size that is most economical for your testing needs.

    Techinical Specifications of AS3-72 SERIES THREE-ZONE Thermal Shock Test Chambers
    Performance is based on ambient temperature +25 ℃ or circulating water temperature +25 ℃, empty load no specimen.
    ModelAS3-
    72A72B72C
    PerformanceTemperature Range-55℃ to +180℃-70℃ to +180℃-75℃ to +180℃
    Temperature Fluctutation≤±0.5℃ (at a steady temperature)
    Temperature Uniformity≤±1.5℃
    Temperature Deviation≤±1.5℃
    Temperature Overshoot≤±2.0℃
    Thermal Shock Temp. Range-40℃ to +150℃
    Hot: +60℃ to +150℃
    Cold: -40℃ to -10℃
    -55℃ to +150℃
    Hot: +60℃ to +150℃
    Cold: -55℃ to -10℃
    -65℃ to +150℃
    Hot: +60℃ to +150℃
    Cold: -65℃ to -10℃
    Test Room Temp. Range-40℃ to +150℃-55℃ to +150℃-65℃ to +150℃
    Transfer Time10 Sec.
    Recovery Time≤5min.
    Hot Zone Temp. Range+60℃ to +180℃
    Preheating Time+60℃ to +180℃ in 30min.
    Exposure Time30min.
    Cold Zone Temp. Range-55℃ to -10℃-70℃ to -10℃-75℃ to -10℃
    Precooling Time+20℃ to -55℃ in 45min.+20℃ to -70℃ in 45min.+20℃ to -75℃ in 45min.
    Exposure Time30min.
    Workspace Volume72L
    Workspace Dimensions (WxDxH)mm500500500
    360360360
    400400400
    Exterior Dimensions (WxHxD)mm160016001600
    166016601660
    185018501850
    MaterialInterior#SUS304 stainless steel
    SealImported silicone seal
    InsulationExpanded foam & fiberglass
    ExteriorCold-rolled steel with powder coated surface
    SystemHeatingNichrome resistance wire heater
    RefrigerationMechannical refrigeration system
    ControlPLC Touch-screen Controller
    Noise Level≤70dB (A-weighted sound pressure level measured at a distance of 1.0 meter)
    Allowable Ambient ConditionsTemperature: +5℃ to +35℃;
    Relative humidity: ≤85%RH (No condensation);
    Air pressure: 86kPa to 106kPa.
    Power SupplyAC 380 (1±10%)V (50±0.5)Hz 3 Phase 4 Wire plus Earth Wire
    Cusom options are available.


    Outstanding Features of Three-Zone Thermal Shock Chambers AS3-72 SERIES

    Cabinet
    Welded #SUS304 stainless steel interior
    Cold-rolled steel exterior with powder coated finish
    Welded structural base frame with removable service access panel on three sides for easy maintenance
    Chamber drain
    Direct drive-shaft powered forced air circulation
    No need to move specimen, hot/cold thermal shock by pneumatic dampers
    Low "K" factor urethane foam insulation and fiberglass thermal insulation
    Full opening chamber door with dual silicone sealing gaskets
    Front built-in touch-screen programmable controller
    Chamber fan motors externally located
    Through-wall traveling access port
    Stainless steel shelves
    Heavy duty casters and floor stands for mobility and balance
    Make modifications to structure when necessary allowing for a modular assembly on-site overcome most facility issues

    Heating / Airflow / Cooling Systems
    Efficient open wire nichrome resistance heaters
    Forced interior air circulation with efficient fan motors
    Self-contained Single stage or cascade mechanical refrigeration system
    - France TECUMSEH hermetic reciprocating compressor
    - German GEA (Bock) semi-hermetic reciprocating compressor
    - German BITZER semi-hermetic reciprocating compressor
    - USA Copeland hermetic compressor
    Zero ozone depletion potential (ODP) refrigerants - R404A / R23
    Air cooled condenser / Water Cooled Condenser (Option) / Option Liquid Nitrogen Cooling
    High efficiency brazed plate heat exchanger (Option)
    EMERSON A-W Series oil separators
    Solenoid valves for energy saving refrigeration bypass capacity control
    All piping joints silfosed or silver soldered
    Oil pressure switches


    Optional Accessories
    Custom colors
    Number, size, position and shape (round, glove or square) of traveling access ports
    Additional shelves
    Custom fixture
    Door Interlocks
    Water cooled condenser
    Remote refrigeration system
    Boost cooling system, LN2 or CO2
    Dry air purge
    Dry nitrogen purge
    Quiet package

    3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz





















































































    Quality 3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: ATMARS INDUSTRTY CO., LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)